logo
Nhà Sản phẩmCảm biến pH ORP

High Temperature Resistant PH Sensor For Harsh High Pollution

Chứng nhận
TRUNG QUỐC Suzhou Delfino Environmental Technology Co., Ltd. Chứng chỉ
TRUNG QUỐC Suzhou Delfino Environmental Technology Co., Ltd. Chứng chỉ
Tôi trò chuyện trực tuyến bây giờ

High Temperature Resistant PH Sensor For Harsh High Pollution

High Temperature Resistant PH Sensor For Harsh High Pollution
High Temperature Resistant PH Sensor For Harsh High Pollution High Temperature Resistant PH Sensor For Harsh High Pollution

Hình ảnh lớn :  High Temperature Resistant PH Sensor For Harsh High Pollution

Thông tin chi tiết sản phẩm:
Nguồn gốc: Trung Quốc
Hàng hiệu: Daruifuno
Chứng nhận: CE, ISO
Số mô hình: ASP126E
Thanh toán:
Số lượng đặt hàng tối thiểu: 1
Giá bán: USD25-250
chi tiết đóng gói: Thùng carton
Thời gian giao hàng: 3-10 ngày làm việc
Điều khoản thanh toán: T/T, Liên minh phương Tây, Moneygram
Khả năng cung cấp: 10000 bộ mỗi tháng

High Temperature Resistant PH Sensor For Harsh High Pollution

Sự miêu tả
Tên sản phẩm: cảm biến PH Phạm vi đo lường: 0~14pH
Không (E0) pH: ± 0,25ph % Độ dốc: > 95%
Áp lực làm việc: 0-6 vạch Làm việc tạm thời: 0 ~ 135oC
Đơn vị nhiệt độ: PT100, PT1000, NTC10K tùy chỉnh Kích thước cài đặt: PG13.5
Đuôi chì: Tích phân hoặc chia Dây điện: tiêu chuẩn 5 mét
Ứng dụng: bùn nhớt hoặc khử lưu huỳnh
Làm nổi bật:

high temperature resistant pH sensor

,

harsh environment pH probe

,

high pollution ORP sensor

High Temperature Resistant PH Sensor For Harsh High Pollution

Daruifuno manufactures the rugged, high-performance ASP126E industrial pH electrode for harsh environments.

 

Designed for harsh environments, this sensor provides a reliable pH measurement solution with a measurement range of 0 to 14 pH. Its robust construction and advanced reference system ensure stable and accurate performance even in highly contaminated and high-temperature applications.

 

Superior measurement technology: The core of this pH electrode is a low-impedance cylindrical glass membrane indicator electrode, designed for fast, accurate readings with minimal drift.

 

It is paired with a highly stable reference system utilizing an Ag/AgCl reference electrode and a proprietary non-porous salt bridge with KCl gel.

 

This advanced design is crucial, as its non-porous structure is particularly resistant to poisoning and contamination, making it ideal for harsh, highly contaminated, and high-temperature media.

 

Built for extreme conditions: This electrode stands out for its exceptional tolerance to operating stresses.

It is suitable for a variety of operating conditions and offers flexible operating pressure and temperature specifications: Low-medium ambient: Continuous operation from 0 to 80°C with a maximum operating pressure of 0 to 6 bar.

High-temperature: Continuous operation from 80 to 100°C for up to 60 minutes.

Custom configurations are also available for more extreme applications: Custom low-medium ambient: Continuous operation from 0 to 100°C.

Custom high-temperature: Continuous operation from 100 to 135°C for less than 60 minutes.

This high-temperature specification is certified for reliable operation for over 40 cycles (tested in clear water).

 

Optimized for moderate flow rates, this electrode operates effectively in sample flow rates from 0.001 m/s to 0.5 m/s.

 

Accuracy and Integration: Key measurement specifications guarantee accuracy and performance: zero point (E0) tolerance of 0.25 pH and slope greater than 95%. This sensor seamlessly integrates into your existing system.

 

It features a standard 12mm diameter and 120mm length (custom lengths available), along with an industry-standard PG13.5 mounting thread.For temperature compensation, custom options include PT100, PT1000, or NTC10K.

 

Finally, installation is simplified with a choice of integrated or detachable cable outlet options.

 

Choose this rugged pH electrode for reliable, accurate, and durable performance, minimizing downtime and maximizing process efficiency in the harshest industrial environments.

High Temperature Resistant PH Sensor For Harsh High Pollution 0

Specifications
Model ASP120E ASP121E ASP122E ASP123E ASP124E
Measuring Object PH
Measuring Range 0~14pH
Indicator Electrode low impedance cylindrical glass membrane
Reference System Ag/AgCl reference electrode, double salt bridge, KCl gel
Electrode Material Glass+Dot-shaped ceramic hole Glass+Dot-shaped ceramic hole Glass+Dot-shaped ceramic hole Glass+Porous tetrafluoro ring Glass+ceramic sand core
Working Pressure Medium and low temp environment: max. 0~6bar High temp environment: 0~3bar
Working Temp. Medium and low temp. environment: 0~80℃, continuous work High temp. environment: 80~100℃, continuous work for less than 60 minutes Customzied as below : Medium and low temp. Env.: 0~100℃, continuous work High temp. Env.: 100~135℃, continuous work < 60 mins High temp. Env. work more than 40 times (clean water test env.)
Sample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Zero (E0) ±0.25pH
SLOP% >95%
Temperature Unit PT100, PT1000, NTC10K customized
Dimension Standard: diameter 12mm/Length 120mm (customized)
Installation Thread PG13.5
Tail Lead Integral or split
Application Strong acid and alkali Normal temp. pure water >5μS/cm Harsh industrial process* Normal temp. desulfurization or viscous slurry Hydrofluoric acid with concentration ≤4000ppm
Model ASP125E ASP126E ASP127E ASR120E ASP128E
Measuring Object PH PH PH ORP PH
Measuring Range 0~14pH 0~14pH 0~14pH ±2000mV 0~14pH
Indicator Electrode low impedance cylindrical glass membrane low impedance cylindrical glass membrane low impedance cylindrical glass membrane Platinum glass membrane
Reference System Ag/AgCl reference electrode, double salt bridge, KCl gel
Electrode Material Glass+ceramic sand core
Working Pressure Medium and low temp environment: max. 0~6bar High temp environment: 0~3bar max. 0~6bar
Working Temp.

Medium and low temp. environment: 0~80℃, continuous work

High temp. environment: 80~100℃, continuous work for less than 60 minutes

Customzied as below :

Medium and low temp. Env.: 0~100℃, continuous work

High temp. Env.: 100~135℃, continuous work < 60 mins High temp. Env. work more than 40 times (clean water test env.)

-15~80℃, continuous work
Sample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Zero (E0) ±0.25pH
SLOP% >95%
Temperature Unit PT100, PT1000, NTC10K customized
Dimension Standard: diameter 12mm/Length 120mm (customized)
Installation Thread PG13.5
Tail Lead Integral or split
Application Strong acid and alkali Harsh conditions &high pollution Fermentation process High temp. Industrial process Low temp.
Features & Advantages
  • Large capacity reference for extended service life
  • Optional cleaning connector for underwater maintenance
  • Available with PTFE protective cover and self-cleaning interface
  • Self-cleaning function enhances stability, accuracy, and reliability while reducing maintenance costs
High Temperature Resistant PH Sensor For Harsh High Pollution 1
The ASP126E glass pH sensor offers ultimate flexibility with custom mounting accessories for pure water environment:
  • Sidewall Mounting: Ideal for large tanks and vessels
  • Top Flange Mounting: Perfect for sealed reactors
  • Pipe/Flow Cell Mounting: For in-line measurements
  • Submersible Mounting: For open tanks and channels
  • Manual Retractable Holder: Enables maintenance without process shutdown
High Temperature Resistant PH Sensor For Harsh High Pollution 2
The optional PTFE (Teflon) sheath. Featuring 3/4" NPT threads for easy attachment to mounting accessories, it ensures seamless integration across various applications.
Application For Pure Water >5μS/Cm
Application For Pure Water >5μS/Cm
High Temperature Resistant PH Sensor For Harsh High Pollution 4
High Temperature Resistant PH Sensor For Harsh High Pollution 5
High Temperature Resistant PH Sensor For Harsh High Pollution 6

Chi tiết liên lạc
Suzhou Delfino Environmental Technology Co., Ltd.

Người liên hệ: Yuki Fu

Tel: +8615716217387

Gửi yêu cầu thông tin của bạn trực tiếp cho chúng tôi (0 / 3000)

Sản phẩm khác